Please note our upcoming 4th of July holiday hours for all S. G. Torrice locations. Friday, July 1st: 7:00 AM - 3:00 PM. Boston location hours will be 6:00 AM - 3:00 PM. Monday, July 4th: Closed. Our regular business hours will resume on Tuesday, July 5th. For emergencies, you may contact our after-hours hotline at 978-284-3309.

First Co. 48HBXB-HW-TXV410

First® HBXB-HW 48HBXB-HW-TXV410 Hydronic Air Handler with TXV Metering, 48000 Btu/hr BTU, 120 V, 10.7 A, 3/4 hp

  • Manufacturers: First Co.
  • Brand Name: First Co.
  • Item #: 2438
  • MPN: 48HBXB-HW-TXV410
  • Qty. Interval: 1
  • Availability: Login for Availability

First® Hydronic Air Handler with TXV Metering, Series: HBXB-HW, 48HBXB-HW Model, 4 ton Nominal, 48000 Btu/hr BTU, 120 V, 10.7 A, 3/4 hp, Configuration: Vertical/Horizontal/Counterflow, 15 SEER, 7/8 in Suction, 1/2 in Liquid Connection, R-410A Refrigerant, 15 A Fuse, 20 x 25 x 1 in Filter, Baked-On Powder-Coated, 21-1/4 in W x 48 in H x 28 in D

Model      :      48HBXB-HW
Nominal Capacity      :      4 ton
BTU Rating      :      48000 Btu/hr
Voltage Rating      :      120 V
Amperage Rating      :      10.7 A
HP Rating      :      3/4 hp
Configuration      :      Vertical/Horizontal/Counterflow
SEER Rating      :      15
Connection Type      :      7/8 in Suction, 1/2 in Liquid
Refrigerant Type      :      R-410A
Fuse Rating      :      15 A
Filter Size      :      20 x 25 x 1 in
Finish      :      Baked-On Powder-Coated
Dimensions      :      21-1/4 in W x 48 in H x 28 in D
  • Multi-function micro-processor circuit board
  • Blower start relay - eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
  • Manual air vent on hot water coil
  • Blower door shut-off switch
  • Slide out hot water coil for easier service
  • Two-speed fan operation
  • Convertible horizontal drain pan
  • Piston-type metering device (standard)
  • Copper tube heating and cooling coils
  • Compatible with all major brands of split condensing units and heat pumps
  • Primary and secondary condensate drain connections
  • Factory installed filter drier
  • 1 in filter easily accessible
  • Without pump

    • Aprilaire 8463
    • Aprilaire® 8400 8463 Thermostat, 24 VAC, 1 - 2.5 A, 5-1-1, 5-2 day Program Programmabili...

    • Item #: 24015
    • MPN: 8463
    • UPC: 686720846304
    • First Co. 36HBXB-H...
    • First® HBXB-HW 36HBXB-HW-TXV410 Hydronic Air Handler with TXV Metering, 36000 Btu/hr BTU...

    • Item #: 2221
    • MPN: 36HBXB-HW-TXV410